X-Ray Flaw Detector General Purpose


Product Description

X-Ray Flaw Detector General Purpose

Application:
Our Portable X-ray Non-destructive Testing Equipments are the ideal inspection instruments used in the field of oil pipeline, chemical, aviation, astronavigation, mechanism, boiler, pressure container, shipbuilding, and national defense industries.
Features:
1. An overall self-diagnosis for software and hardware after startup can effectively detect the failure component.
2. Strong anti-interference properties make our X-ray Equipment can also work with electric generator in the wild field.
3. Quickly and exactly set exposure parameters by manual button.
4. High voltage can be started delayed to make enough time for personnel evacuate.
5. Slowly increase and decrease high voltage to protect X-ray generator
6. The ratio of working and rest is 1:1
Order Number Serials:
XXQ: Directional X-Ray Flaw Detector + Glass Tube
XXG: Directional X-Ray Flaw Detector + Ceramic Tube
XXH: Weeks to X-Ray Flaw Detector + Flat Target
XXHA: Weeks to X-Ray Flaw Detector + Cone Target
Model
XXQ-1005
XXH-1005
XXQ-1605
XXH-1605
XXG-1605
XXQ-2005
XXG-2005
XXH-2005
XXHA-2005
XXQ-2505
XXG-205
XXH-2505
XXHA-2505
XXQ-3005
XXG-3005
XXH-3005
XXHA-3005
XXQ-3505
XXG-3505
XXH-3505
XXHA-3505
Power supply
AC220V+-10%    50Hz
Power (kW)
>1.0
>1.5
>2.5
>2.5
>3.0
>3.5
Tube voltage (kVp)
 
60-160
80-200
130-250
150-300
200-350
Max. Tube current (mA)
5
5
5
5
5
5
Focal Spot Size mm x mm
Q.G
1.0*1.0
1.5*1.5
1.5*1.5
2.0*2.0
2.5*2.5
2.5*2.5
H
1.0*1.5
1.0*2.0
1.0*2.0
1.0*2.4
1.0*2.5
1.0*2.5
HA
1.0*2.5
1.0*3.5
1.0*3.5
1.0*5.0
1.0*6.0
1.0*6.0
Weight kg
Tube
Q
11
15
20
35
44
44
G
 
14
20
32
37
37
H.HA
11
15
20
35
44
44
Controller
11
Radiation angle of X-ray
Q
40º
G
360º x 25º
H.HA
360º x 30º
Max. penetration A3 steel (mm)
Q. G
8
20
29
39
49
59
H
6
18
26
36
46
56
HA
 
15
24
34
40
50
Insulation
SF6  gas
Environmental temperature
-25℃ ~ +40℃
Relative Humidity 
No more than 85%
Working conditions of X-Ray photography
1. Focus to Film: 600mm
2. Exposure time: 5 min
3. Film: Tianjin Model III, intensified by double lead foil.
4. Treatment in the darkroom: Temp. 20 +/-2ºC, 5 min. blackness ≥ 1.5
Safe working pressure of gas 0.35 ~ 0.50Mpa (Operation will be prohibited in the case less than 0.35Mpa)