ION321-Pb Portable Sodium Ion Meter


Product Description

ION321-Pb Portable Lead Ion Meter

 

Features:

1. High performance portable fluoride ion meter is equipped with a large LCD display.

2. 2 to 5 points calibration from low to high concentrations.

3. Direct ion concentration readout simplifies the elaborate measurement process.

4. Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L.

5. Automatic Temperature Compensation provides accurate reading over the entire range.

6. Calibration Due Reminder prompts user to calibrate the meter regularly.

7. Stability indicator automatically shows current measurement status.

8. Auto-Hold function freezes stable reading for easy viewing and recording.

9. Manual temperature calibration improves the measurement accuracy of meter.

10. Selectable temperature unit (°C or °F) meets different application requirements.

11. mV measurement mode allows user to check performance of the ion selective electrode.

12. Automatic electrode diagnosis shows the slope of sensor.

13. Help message as a operational guide that helps you quickly begin using the meter.

14. System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc.

15. Reset feature automatically resumes all parameters back to factory default settings.

16. Expanded memory stores and recalls up to 500 readings.

17. Built-in real-time clock stamps stored data to meet GLP standard.

18. Stored data can be transferred into computer by USB communication interface.

19. Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly.

Model

 ION321-Pb
lon
Range1x10-8~0.1M, 0.2~20700ppm
Accuracy±1% F.S
Resolution0.001, 0.01, 0.1, 1
Calibration Points2 to 5 points
Calibration Solutions0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L
mV
Range-1999.9~1999.9mV
Accuracy±0.2mV
Resolution0.1mV
Temperature
Range0~105°C, 32~221°F
Accuracy±0.5°C, ±0.9°F
Resolution0.1°C
Calibration RangeMeasured value ±10°C
Temperature Units°C or °F
Others
Temperature Compensation0~100°C, 32~212°F
Compensation ModeManual or Automatic
Hold FunctionManual or Automatic
Stability ConditionsLow or High
Calibration Due0 to 31 days
Power OffManual or Automatic (10, 20, 30 minutes)
Reset FunctionYes
MemoryStores up to 500 data sets
OutputUSB Communication Interface
ConnectorBNC
Power Requirements3x1.5V "AA" Batteries
Battery LifeApproximately 150 hours (Turn off the backlit)
Dimensions170(L)x85(W)x30(H)mm
Weight300g