Portable pH/mV/Temp Meter PH-320


Product Description

Portable pH/mV/Temp Meter PH-320

PH-320 is a multi-parameter ion meter used for measuring the ion concentration and pH value of liquids. The meter is equipped with a BNC connecter that can connects various combination Ion Selective Electrodes.

Features:
1. During the pH mode, Up to 5 points push-button calibration with auto-buffer recognition.
2. Selectable pH buffer standards and temperature units.
3. Automatically calculates and displays electrode slope after calibration.
4. During ORP mode, Single point offset calibration allows user adjusts displayed value to a known standard.
5. Absolute or Relative millivolt (R.mV) measurement provides accurate ORP readings.
6. During the ion mode, 2 to 5 points push-button calibration from low to high concentrations.
7. Selectable multiple concentration units, including ppm, mg/L and mol/L.
8. Direct readout ion concentration simplifies the elaborate measurement process.
9. Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range.
10. Automatic endpoint function freezes the stable measured values for easy reading and recording data.
11. Calibration due reminder prompts you to calibrate the meter regularly.
12. Manual temperature calibration provides accurate temperature value.
13. Help message as a operational guide to helps you understand how to use meter.
14. Setup menu lets user customizes buffer standards, calibration points, stability conditions, resolution, measurement units, date and time to meet measurement requirements.
15. Reset function can resumes all settings to factory default values.
16. Expanded memory stores and recalls up to 500 readings.
17. Built-in real-time clock stamps stored data to meets GLP standards.
18. Stored data can be transferred into computer via USB communication. 
 
Specifications:
1. pH Range: -2.000~20.000pH 
2. pH Accuracy: ±0.002pH 
3. Resolution: 0.001, 0.01, 0.1pH, Selectable 
4. Calibration Solutions: USA (pH1.68/4.01/7.00/10.01/12.45), NIST (pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/12.75) 
5. Ion Concentration Range: 0.001~19999ppm, mg/L or mol/L (Depending on measuring range of Ion Selective Electrode) 
6. Ion Concentration Accuracy: ±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent) 
7. Calibration Points: 2 to 5 points 
8. Calibration Solutions: 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L 
9. mV Range: -1999.9~1999.9mV 
10. mV Accuracy: ±0.2mV 
11. Resolution: 0.1, 1mV, Selectable 
12. Temperature Range: 0~105°C, 32~221°F 
13. Temperature Accuracy: ±0.5°C, ±0.9°F 
14. Temperature Calibration: Manual 
15. Temperature Compensation: 0~100°C, 32~212°F, Automatic or Manual 
16. Auto-Off: Manual or Automatic (10, 20, 30 minutes after last key pressed, Selectable) 
17. Hold Function: Manual or Automatic 
18. Stability Conditions: Low or High, Selectable 
19. Calibration due reminder: 0 to 30 days 
20. Reset Function: Yes 
21. Memory: 500 data sets with Date/Time stamping 
22. Output: USB Communication Interface 
23. Connector: BNC 
24. Power Requirements: 3 x 1.5V "AA" Batteries 
25. Battery Life: Approximately 150 hours 
26. Dimensions: 170(L)x 85(W)x 30(H)mm 
27. Weight: 300grams