EC911 Benchtop pH/Ion/Conductivity/DO Meter
Order Information:
1. EC911: pH, Cond./TDS/Salinity/Res. Sensor Made in China.
2. EC911X: pH, Con./TDS/Salinity/Res. Sensor Made in UK.
Professional benchtop pH meter, containing 17 setting options, suitable for measuring pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and DO.
pH Mode:
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and zero offset.
ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.
Ion Concentration Mode:
• 2 to 5 points calibration, including the selection of 8 concentration points.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Direct ion concentration readout simplifies the measurement process.
• Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.
Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and
pure water compensations, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement errors.
Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-read function senses and locks the measurement endpoint.
• Calibration due alarm reminds the user to calibrate the meter regularly.
• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,
date and time, auto-power off, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface for data transfer and timed interval readings.
Specifications:
pH:
1. Range: -2.000 to 20.000 pH
2. Resolution: 0.001/ 0.01/ 0.1pH, selectable
3. Accuracy: ±0.002 pH
4. Calibration: 1 to 5 points
5. pH Buffer Options: USA/ NIST/ DIN/ 2 custom buffers
ORP:
1. Range: -1999.9 to 1999.9 mV
2. Resolution: 0.1/ 1mV, selectable
3. Accuracy: ±0.2mV
4. Calibration: 1 point
5. Measurement Modes: Relative / Absolute mV
Ion Concentration:
1. Range: 0.00 to 19999 (depending on the range of ISE)
2. Resolution: 0.001, 0.01, 0.1, 1, automatic
3. Accuracy: ±0.5% F.S. (monovalent), ±1% F.S. (divalent)
4. Calibration: 2 to 5 points
5. Calibration Solutions:0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000
6. Measurement Units: ppm, mg/L, mol/L, mmol/L
Conductivity:
1. Range: 0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0mS/cm
2. Resolution: 0.001, 0.01, 0.1, 1, automatic
3. Accuracy: ±0.5% F.S.
4. Calibration: 1 to 5 points
5. Calibration Solutions: 10µS / 84µS / 1413µS / 12.88mS / 111.8mS
6. Temperature Coefficient: 0.0 to 10.0%/°C
7. Pure Water Compensation: Yes
8. Reference Temperature: 20/ 25°C
9. Cell Constant: K=0.1/ 1/ 10/ Custom
TDS:
1. Range: 0 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt
2. Resolution: 0.01, 0.1, 1, automatic
3. Accuracy: ±1% F.S.
4. TDS Conversion Factor: 0.1 to 1.0 (default 0.5)
Salinity:
1. Range: 0.00 to 80.00ppt / 0.00 to 42.00psu
2. Resolution: 0.01
3. Accuracy: ±1% F.S.
Resistivity:
1. Range: 0.00 to 20.00MΩ
2. Resolution: 0.01
3. Accuracy: ±1% F.S.
Dissolved Oxygen:
1. Range: 0.00 to 20.00mg/L / 0.0 to 200.0 % saturation
2. Resolution: 0.01/ 0.1, selectable
3. Accuracy: ±0.2mg/L / ±2.0%
4. Calibration: 1 or 2 points
5. Pressure Correction: 60.0 to 112.5kPa / 450 to 850mmHg, manual
6. Salinity Correction: 0.0 to 50.0g/L, manual
Temperature:
1. Range: 0 to 105°C / 32 to 221°F
2. Resolution: 0.1°C/°F
3. Accuracy: ±0.5°C / ±0.9°F
4. Calibration: 1 point
5. Calibration Range: Reading ±10°C/°F
Other Specifications:
1. Temperature Compensation: 0 to 100°C / 32 to 212°F, manual or automatic
2. Hold Function: Manual / Auto-read measurement endpoint
3. Stability Criteria: Low / High
4. Calibration Due Alarm: 1 to 31 days or off
5. Memory: Stores up to 500 data sets
6. Output: USB communication interface
7. Connector: BNC, 6-pin mini-DIN, 3.5 mm jack socket
8. Display: Custom LCD (125 × 100 mm)
9. Power Supply: 5V DC power adapter
10. Environmental Conditions: 0 to 50°C/ 32 to 122°F, relative humidity < 80%
11. Dimensions: 210 × 188 × 60mm
12. Weight: 1.5kg