Hand Held Refractometers
The Hand Held Refractometers are specially designed for measuring the concentration of many kinds of solution listed as following: Juices, Beverages, Honey, Salt water, Brine, Cleaning fluid, battery fluid, Antifreeze and Industrial fluids etc. And they can also test for the proportion of the water-soluble solution. They can be easily used and they are competitive in price. You only need to drop some liquid on the prism and then make it towards to the sunlight. Then the reading of the concentration will appear. ATC means Automatic Temperature Compensation.
1. For Brix
| Model | Range | Resolution | Accuracy |
| RHB-80ATC | Brix 0~80% | 0.5% | ±0.5% |
| RHB-90ATC | Brix 0~90% | 0.5% | ±0.5% |
| RHB-90S | Brix 0~42; 42~71; 71~90% | 0.2% | ±0.2% |
| RHB-80S | Brix 0~50; 50~80% | 0.2% | ±0.2% |
| RHB-10ATC | Brix 0~10% | 0.10% | ±0.10% |
| RHB-18ATC | Brix 0~18% | 0.10% | ±0.10% |
| RHB-20ATC | Brix 0~20% | 0.10% | ±0.10% |
| RHB-32ATC | Brix 0~32% | 0.20% | ±0.20% |
| RHB-50ATC | Brix 0~50% | 0.5% | ±0.5% |
| RHB-62ATC | Brix 28~62% | 0.2% | ±0.2% |
| RHB-82ATC | Brix 45~82% | 0.5% | ±0.5% |
2. Beer Refractometer
| Model | Rang | Min.Div. | Accuracy |
| AMR008 | Brix: 0~32% | 0.2% | ±0.2% |
| SG: 1.000~1.120 | 0.001 | ±0.001 |
3. Salinity Refractometer
| Model | Range | Resolution | Accuracy |
| RHSA-4ATC | Salinity 0~40‰ | 1‰ | ±1‰ |
| Gravity 1.000~1.030 | 0.001 | ±0.001 | |
| RHS-10ATC | Salinity 0~100‰ | 1‰ | ±1‰ |
| Gravity 1.000~1.070 | 1‰ | ±1‰ | |
| RHS-10BATC | Brix 0~10% | 0.2% | ±0.2% |
| Salinity 0~100‰ | 1‰ | ±1‰ | |
| Gravity 1.000-1.070 | 0.001 | ±0.001 | |
| RHS-28ATC | Salinity 0~28% | 0.2% | ±0.2% |
| RHS-28BATC | Salinity 0~28% | 0.2% | ±0.2% |
| Brix: 0~32% | 0.2% | ±0.2% | |
| RHS-35ATC | Salinity 0~35% | 0.5% | ±0.5% |
Note: RHSA-4ATC popular for aquarium; RHS-35ATC popular for food indstry.
4. Clinical Protein Refractometer
| Model | Range | Resolution | Accuracy |
| VUR1T | Serum Protein 0~12g/dl | 0.2 | ±0.2 |
| Urine Gravity 1.000~1.040sg | 0.002 | ±0.002 | |
| VUR2T | Serum Protein 0~12g/dl | 0.2 | ±0.2 |
| Urine Gravity 1.000~1.050sg | 0.002 | ±0.002 | |
| Refractive Index1.3330~1.3600RI | 0.0005 | ±0.0005 | |
| VUR3T | Serum Protein 0~12g/ml | 0.2 | ±0.2 |
| Urine Gravity 1.000~1.050UG | 0.002 | ±0.002 | |
| Refractive Index: 1.3330~1.3600nD | 0.0005 | ±0.0005 | |
| VUR4T | Serum Protein: 0~12g/dl | 0.2 | ±0.2 |
| Urine Gravity 1.000~1.040UG | 0.002 | ±0.002 | |
| Refractive Index 1.3330~1.3600nD | 0.0005 | ±0.0005 |
5. PET (CAT, DOG) Clinical Protein Refractometer
| Model | Rang | Min.Div. | Accuracy |
| AMR016 | Serum Protein/Plasma: 2~14gms/100ml | 0.1 | ±0.1g/dl |
| Cat Urine Gravity: 1.000~1.060 | 0.001 | ±0.001sg | |
| Dog Urine Gravity: 1.000~1.060 |
6. Automotive AdBlue / DEF Urea Concentration Test Meter
| Model | Range | Min Div. | Remark |
| AMR001 | Urea: 0~40% | 0.2% | ATC, Urea 32.5% |
| AMR002 | Urea: 0~40% | 0.2% | ATC, Urea 32.5% |
| EG: -60°F ~ 32°F | 10°F | ATC | |
| PG: -50°F ~ 0°F | 10°F | ||
| AMR003 | Urea: 0~40% | 0.2% | |
| EG: -50°C ~ 0°C | 5°C | ||
| PG: -50°C ~ 0°C | 5°C | ||
| CW: -40°C ~ 0°C | 10°C | ||
| AMR004 | Urea: 30-35% | 0.2% | |
| EG: -50°C ~ 0°C | 5°C | ||
| PG: -50°C ~ 0°C | 5°C | ||
| CW: -40°C ~ 0°C | 10°C | ||
| BF: 1.10 ~ 1.40Kg/L | 0.01Kg/L |
7. Milk Refractometer
| Model | Range | Min. Div. | Remark |
| AMR005 | Soy Milk: 0~25% | 0.5% | ATC |
| Brix: 0~32% | 0.2% | ||
| AMR006 | Water in Milk: 0~20% | 0.2% | ATC |
8. Battery/Antifreeze/Cleaning Fluid Refractometer
| RHA-100ATC | Ethylene Glycol: -84°F~32°F Propylene Glycol: -60°F~32°F Battery: 1.100~1.400sg | Ethylene Glycol: 5°F Propylene Glycol: 5°F Battery: 0.01sg | Ethylene Glycol: ±5°F Propylene Glycol: ±5°F Battery: ±0.01sg | ATC |
| RHA-200ATC | Ethylene Glycol: -60°C~0°C Propylene Glycol: -50°C~0°C Battery: 1.100~1.400sg | Ethylene Glycol: 5°C Propylene Glycol: 5°C Battery: 0.01sg | Ethylene Glycol: ±5°C Propylene Glycol: ±5°C Battery: ±0.01sg | ATC |
| RHA-503C | Battery: 1.100~1.400sg Ethylene Glycol: -50°C~0°C Propylene Glycol: -50°C~0°C Cleaner: -40°C~0°C | Battery: 0.01sg Ethylene Glycol: 5°C Propylene Glycol: 5°C Cleaner: 5°C | Battery: ±0.01sg Ethylene Glycol: ±5°C Propylene Glycol: ±5°C Cleaner: ±5°C | ATC |
| VBC8 | B: 1.000~1.400sg A: 0%~100% F: -60°C~0°C | 0.01sg 5% 5°C | ±0.01sg ±5% ±5°C | ATC |
9. Brake Fluid Checker
| Model | Range | Min.Div. | Remark |
| VBK1 | DOT3: 1~6% Moisture Boiling Point: 250~500°F Super DOT3: 1-6% Moisture Boiling Point: 250-570°F | 1% | ATC |
| VBK2 | DOT3: 1-6% Moisture Boiling Point: 125-275°C Super DOT3: 1-6% Moisture Boiling Point: 150-275°C | 1% | ATC |
10. Alcohol Refractometer
| Model | Range | Min.Div. | Accuracy |
| RHW-80 | w/w: 0-50%, 50-80% | 0-50%: 1%; 50-80%: 2.5% | ±1% |
11. Refractive Index
| Model | Range | Min.Div. | Accuracy |
| VND1 | nD.1.333-1.520 | 0.001 | ±0.002 ATC |
| VND2 | nD.1.333-1.380 | 0.001 | ±0.002 ATC |
| VND4 | nD.1.435-1.520 | 0.001 | ±0.002 ATC |
12. Bee Honey Refractometer
| Model | Range | Min.Div. | Accuracy |
| RHH13-25 | water: 13~25% | water: 0.1% | water: ±0.1% |
| RHH12-30 | water: 12~30% | water: 0.1% | water: ±0.1% |
| RHH-92ATC | Brix: 58~92% Baume: 38~43Be' water: 12~27% | Brix: 0.5% Baume: 0.5Be' Water: 1% | Brix:: ±0.5% Baume: ±0.5Be' Water: ±1% |
| RHH-90ATC | Brix: 58~90% Baume: 38~43Be' water: 12~27% | Brix: 0.5% Baume: 0.5Be' Water: 1% | Brix: ±0.5% Baume: ±0.5Be' Water: ±1% |
13. Wine Refactometer
| Model | Range | Min.Div. | Accuracy | Remark |
| RHW-25aATC | Alcohol 0~25%VOL | Alcohol 0.2% | Alcohol ±0.2% | ATC |
| Baume 0~20Baume | Baume 0.2 be' | Baume ±0.2 be' | ||
| RHW-25ATC | Alcohol 0~25% | Alcohol 0.2% | Alcohol ±0.20% | ATC |
| RHW-25bATC | Alcohol 0~25%VOL | Alcohol 0.2% | Alcohol ±0.2% | ATC |
| Brix 0~40% | Brix 0.2% | Brix ±0.2% | ||
| RHBS-32aATC | Brix 0~32% | Brix 0.2% | Brix ±0.2% | ATC |
| Oechsle 30~140°Oe | Oechsle 1.0°Oe | Oechsle ±1.0°Oe | ||
| RHBS-32ATC | Brix 0~32%Mas Sacch | Brix 0.2% | Brix ±0.2% | ATC |
Oechsle 0~140°Oe | Oechsle 1.0°Oe | Oechsle ±1.0°Oe | ||
KMW 0~27° (Babo) | KMW 0.2° | KMW ±0.2° | ||
| RHBS-44ATC | Brix 0~44% | Brix 0.4% Oechsle: 2.0°Oe KMW: 0.4° | Brix: ±0.4% Oechsle: ±2.0°Oe KMW: ±0.4° | ATC |
Oechsle: 0~190°Oe | ||||
KMW: 0~38° (Babo) |
14. Emulsion Reractometer
| Model | Range | Min.Div. | Accuracy |
| AMR011 | M10: 0~15% | 0.5% | ±0.5% |
| MDT: 0-15% |
15. Contact Lens Refractometer
| Model | Range | Min.Div. | Accuracy |
| AMR012 | 35~80% | 1% | ±1% |
16. IPA (Iso-Propyl Alcohol) Refractometer
| Model | Range | Min.Div. | Accuracy |
| AMR015 | 0~60% (v/v) | 1% | ±1% |
| -23°C~0°C | 1°C | ±1°C |